BOILER TUBES
Production Range Manufacturing Standards

External Diameter :
21.3 mm - 88.9 mm

Wall Thickness :
2.0 mm - 4.5 mm

Length :

7 m (standart).

TS 11004, DIN 17177, ASTM A-178, TS EN 10217

Special material is used in the manufacturing of the boiler tubes; the internal cover is taken, annealed and passed from 100% magnetic test (Eddy Current and Ultrasonic test).
It is delivered in 7 m length by varnishing

Change of the Flow Limit of Boiler Tubes
Steel Wall Thickness mm %0.2 Flow limit
Short display Material No 200 ºC 250 ºC 300 ºC 350 ºC 400 ºC 450 ºC
N/mm² min.
Fe 37.8
Fe 42.8
1.0315
1.0498
£ 16
£ 16
185
205
165
185
140
160
120
140
110
130
105
125
The Mechanical Properties of Boiler Tubes
Çeliğin Tensile Strength N/mm² The flow limit up to 16 mm Wall Thickness is N/mm² min. Breaking extension (Lº=5xdº)
Short display Material No Longways % Vertical min.%
Fe 37.8
Fe 42.8
1.0315
1.0498
360-480
410-530
235
255
25
21
23
19
*The values given *External Diameters £ 30 mm, Wall Thickness £ 3 pipes are 10 N/ mm² smaller.
Usage
  • Operating Pressure
    Up to 63,5 mm External Diameters 80 bar – after 63,5 mm External Diameter 32 bar

  • Operating Temperature
    max.450 ºC

 